Reducing Adapter Large Mouth

9 sizes
9 sizesSpecification
Borosilicate 3.3Material
Request a Quote

Reducing Adapter Large Mouth, made of Borosilicate 3.3. 9 standard sizes.

  • Borosilicate 3.3
Material per specification Custom sizes available Samples available Bulk & OEM supply Selection support

Check the item is clean and free of cracks or chips before use; avoid thermal shock and mechanical impact; specifications are subject to quotation.

BRAND IDENTITY

Vissal® brand wordmark RichTech company logo

Vissal® is RichTech's own brand; RichTech is the company mark. Both are used together for this product's brand identification.

We will follow up on your inquiry as soon as possible. Custom sizes supported Samples available

Specifications

Reducing Adapter Large Mouth · Specifications

The following are common specifications. Custom joint combinations available upon request.

Request custom specs
SpecificationMaterial
14.10Borosilicate 3.3
19.10Borosilicate 3.3
19.14Borosilicate 3.3
24.10Borosilicate 3.3
24.14Borosilicate 3.3
24.19Borosilicate 3.3
29.14Borosilicate 3.3
29.19Borosilicate 3.3
29.24Borosilicate 3.3

Product Description

1. Overview

The Reducing Adapter Large Mouth belongs to our standard taper joint range and is mainly used for connecting, diverting, reducing or sealing standard taper joints. Standard sizes cover 14/10 起. Building blocks for distillation, reflux and extraction set-ups.

The body is made of borosilicate 3.3 glass; coefficient of expansion about 3.3×10⁻⁶/K, clearly better thermal shock resistance than soda-lime glass. It works between -30℃ to 150℃ (thermal shock within 120℃); chemically it resists water, acids, salt solutions and most organic solvents; not for hydrofluoric acid, hot concentrated phosphoric acid or strong alkali; smooth transparent wall, low adhesion. Level, interface and residue are easy to read, keeping transfer errors small.

When selecting, confirm medium, temperature and connection first, then fix the size: the medium decides the material, the temperature decides whether heating or autoclaving is possible, and the connection decides whether it mates with existing apparatus. For duties outside the normal range — hot concentrated alkali, fluoride media, vacuum or repeated thermal cycling — our engineers can confirm a suitable option.

2. Key properties

  • Material: borosilicate 3.3 glass
  • Working temperature: -30℃ to 150℃ (thermal shock within 120℃)
  • Chemical resistance: resists water, acids, salt solutions and most organic solvents; not for hydrofluoric acid, hot concentrated phosphoric acid or strong alkali
  • Surface: smooth transparent wall, low adhesion
  • Sterilisation: autoclavable (121℃) or dry-heat sterilizable
  • Size range: 14/10 起 (9 种规格)

3. Manufacturing and inspection

Parts are lamp-worked and blown from borosilicate tube or rod, annealed as a whole to relieve forming stress; joints and sealing faces ground in pairs, keeping items of the same size interchangeable. Work is carried out at controlled stations to prevent scratches and cross-contamination.

Each item is checked for appearance, dimensions and fit before dispatch; sampling covers capacity or graduation deviation, joint fit and wall uniformity. Items from the same batch stay consistent in size and feel, which simplifies central storage and reordering. Inspection records and batch information are available with the goods.

Applications

Typical applications

synthesis, distillation and reflux

Handles assembling with other standard-joint parts in synthesis, distillation and reflux and is a common supporting item in such workflows.

Routine preparation and sampling

Suited to solution preparation and sample transfer in daily work.

Incoming and batch comparison

Used for incoming checks and batch-to-batch consistency comparison.

Teaching and training

Straightforward structure and low operating threshold suit demonstrations and onboarding.

Transfer during sample prep

Carries material between weighing, dissolving, transfer and make-up, cutting cross-contamination and losses.

Method and workflow validation

In method development it supports replicate runs with one consistent vessel format, reducing systematic error.

Selection Guide

Choose by duty

Duty first, size second

Define the handling method, contact medium and temperature range before choosing material and interface.

Interface must match

Confirm the interface form before pairing with other apparatus; mismatches leak or will not assemble.

Material by medium

Choose material according to the contact medium and operating temperature; refer to the specification block.

Special requirements on request

Non-standard sizes, special interfaces or volume customisation are quoted separately.

Size versus throughput

Match size to the volume per run and the number of runs a day; oversize vessels add cleaning load, undersize ones force repeated batches.

Reading accuracy needed

Choose graduated or single-mark items when accurate metering matters; skip the accuracy premium for rough transfer work.

Service condition guide

ConditionSuitabilityNotes
Ambient storage and transferSuitableacids, salt solutions and organic solvents for long contact
Water bath or heating mantleSuitableheat gradually to avoid local overheating
Direct flameConditionaluse a wire gauze or mantle, never heat dry
Rapid heating or coolingConditionalkeep single-step shock within 120℃; thick walls need slower ramps
Vacuum serviceConditionalonly heavy-wall or purpose-made items; thin walls are not recommended
Hydrofluoric acid / fluoridesNot suitableattacks the glass matrix; use PTFE or PP instead
Hot concentrated alkali or phosphoric acidNot suitableprolonged contact etches the surface
AutoclavingSuitablestandard 121℃ cycle with moderate ramp rates

Usage Guide

Standard procedure

01

Step 01

Apply a thin film of joint grease or a PTFE sleeve to about half the ground length only, never into the bore

02

Step 02

Engage the joints with a gentle twist in one direction rather than pushing straight in

03

Step 03

Clamp the assembly near the joint root, not on thin-walled sections

04

Step 04

To dismantle, twist gently before pulling; for a seized joint use warm water or a little solvent, never lever it

05

Step 05

Inspect for cleanliness, cracks and chipped edges before use; a crack spreads quickly under heat or load, so retire the item at once and never patch it.

06

Step 06

Assemble as required for assembling with other standard-joint parts and confirm the connection is secure.

07

Step 07

Pour or transfer slowly along the wall to avoid impact on the base and splashing; with volatile or foaming media a slow stream cuts losses and cross-contamination.

08

Step 08

When heating, preheat first and raise the temperature gradually; never heat an empty vessel; avoid thermal shock.

09

Step 09

Clean promptly after use and choose the drying method according to the material; soak stubborn residues first and never scrape the wall with hard tools.

10

Step 10

Before first use, clean according to the material; soak in dilute acid where appropriate, rinse thoroughly and dry. New items may carry processing aids, so clean before contact with samples.

11

Step 11

Store without stacking or impact, in a ventilated and dry place; long stacking deforms the base, and volumetric ware should stand on its own.

12

Step 12

Keep one batch together and label different sizes separately to avoid picking the wrong item; once mixed, the batch is hard to identify when a problem appears.

13

Step 13

Keep a usage log with the commissioning date, media contacted and cleaning method, so replacement timing and traceability stay clear.

Maintenance & Notes

⚠️ Safety & handling notes

Avoid seized joints

Remove joints or insert a paper strip for long storage; alkaline solutions left in place can bind the glass.

Grease quantity

Excess grease contaminates samples and blocks the bore; under vacuum apply sparingly and check the bore.

Avoid thermal shock

Sudden temperature changes create stress, especially in thick walls and wide openings; heat and cool gradually.

Prevent mechanical damage

Avoid impact, dropping and scratching; never carry by a thin or weak section.

Clean promptly

Clean immediately after use; dried residues are harder to remove. Avoid abrasive cleaning tools.

Drying by material

Air-dry or dry at low temperature; volumetric ware must never be oven-dried.

Periodic inspection

Check for cracks, deformation and seal failure after long use and replace when needed.

Identification and traceability

Items should carry a clear label and usage record; mixed use makes cleaning history and media contact untraceable.

Retirement criteria

Stop using an item for critical work once it is cracked, chipped, worn at the graduations or leaking; never patch and return it to service.

Need spec confirmation or bulk pricing?

Request a Quote
Get a Quote