Standard Joint
Thermometer Adapter
Standard Joint · Thermometer Adapter

Thermometer Adapter

Screw Cap · 14# ~ 29# · Fits Φ5.0~7.5mm Thermometers

The thermometer adapter is a specialized component for connecting standard laboratory thermometers to standard taper glassware in organic chemistry setups. The lower end features a precision-ground standard taper joint for secure connection to apparatus such as distillation heads and three-neck flasks, while the upper end uses a threaded nylon cap with an O-ring to form a vacuum-tight seal around the thermometer. Manufactured from high-borosilicate glass 3.3 with precision-ground 1:10 taper joints, the product fully complies with Chinese National Standards (GB/T), US ASTM E, and ISO 3585 standard taper specifications. Available in standard screw-cap, sealed-bottom, and adjustable configurations to suit different experimental requirements.

14 – 34GB/T
14 – 34ASTM
14 – 34ISO
5 – 7.5 mmFits Thermometer O.D.

Specifications are subject to confirmation with your enquiry.

Request a Quote
Borosilicate 3.3 GB · ASTM · ISO Multi‑Standard 1:10 Taper Nylon Cap + O-Ring Seal Fits Φ5.0~7.5mm Thermometers
  • Borosilicate Glass 3.3, thermal shock 280°C
  • Standard 1:10 taper, precision ground
  • GB/T · ASTM · ISO multi‑standard compliant Custom
  • Nylon cap + O-ring, vacuum seal
  • Fits Φ5.0~7.5mm thermometers
  • Standard / Sealed-Bottom / Adjustable options

BRAND IDENTITY

Vissal® brand wordmark RichTech company logo

Vissal® is RichTech's own brand; RichTech is the company mark. Both are used together for this product's brand identification.

We will follow up on your inquiry as soon as possible. Custom sizes supported Samples available

Specifications

Specifications

Thermometer Adapter · Specifications

Standard sizes are listed below. All products comply with GB/T, ASTM, and ISO standard taper systems. Full range 10/19 ~ 60/45 available. Custom adapter types and tube lengths are available.

Request custom specs

1. Screw-Cap Thermometer Adapter (Standard)

GB/TASTMISOFits Thermometer O.D. (mm)Tube Length (mm)Material
Please contact us to confirm the available specifications.

2. Sealed-Bottom Thermometer Adapter

GB/TASTMISOTube Length (mm)FeaturesMaterial
Please contact us to confirm the available specifications.

3. Adjustable Thermometer Adapter

GB/TASTMISOFits Thermometer O.D. (mm)Seal TypeMaterial
Please contact us to confirm the available specifications.

* Joint numbers (14#, 19#) indicate the largest diameter (mm) of the taper. All are 1:10 taper.
* GB/ASTM/ISO designations are different standard identifiers — physical dimensions are identical and fully interchangeable.
* Full range 10/19 ~ 60/45 available upon request.
* Tube lengths can be customized based on reaction vessel depth.
* Some models feature a vent hole for pressure equalization.
* Contact our sales team for MOQ and lead time on custom orders.

✦ Customization Services — We offer custom joint sizes, adapter types, tube lengths, and sealing configurations. Share your specific requirements and our technical team will provide a tailored solution.

Product Description

The thermometer adapter is a precision component for mounting standard laboratory thermometers in standard taper glassware systems. The lower end features a precision-ground standard taper joint for secure connection to apparatus such as distillation heads and three-neck flasks. The upper end features a threaded nylon cap with an O-ring that seals around the thermometer when tightened, creating a reliable vacuum-tight seal and holding the thermometer securely at the desired depth.

Compared to traditional rubber stoppers, the thermometer adapter offers standardized installation, reliable sealing, vertical thermometer positioning, resistance to aging, and convenient installation — significantly improving temperature measurement accuracy and experimental reproducibility.

Key Features

  • Borosilicate Glass 3.3: Meets ISO 3585, low thermal expansion, thermal shock resistance up to 280°C, excellent chemical durability
  • Multi‑Standard Compliance: Precision‑ground 1:10 taper meets GB/T, ASTM E, and ISO 3585 standard taper specifications for full interchangeability
  • Screw Cap Sealing: Nylon cap with O-ring provides reliable seal and allows adjustable thermometer positioning
  • High Transparency: Clear view of thermometer readings and experimental process
  • Standardized Installation: Ensures vertical thermometer positioning for accurate measurements
  • Multiple Configurations: Standard screw-cap, sealed-bottom, adjustable, and stirrer adapter options available

Quality Assurance

Each thermometer adapter is inspected for taper accuracy, seal integrity, and surface finish to ensure reliable connection with all standard joint components. Custom bulk orders are welcome.

Tip: The thermometer adapter fits standard laboratory thermometers with an outer diameter of 5.0~7.5mm. Confirm thermometer diameter before use. Avoid over-tightening the cap to prevent thermometer breakage. Handle glass components with care.

Applications

Typical Uses

Distillation

Mount thermometers in distillation heads to measure vapor temperature and determine boiling ranges

Reflux

Monitor reaction temperature in reflux setups

Melting Point Determination

Secure thermometers in melting point apparatus

Organic Synthesis

Precise temperature monitoring in controlled reactions

Schlenk Line Operations

Temperature monitoring under inert atmosphere

Compatible Equipment

Standard joint distillation heads, fractionating heads, Claisen heads

Three-neck and four-neck flasks

Standard joint condensers

Reactors, Schlenk tubes

Tip: Always use matching standard joint sizes for optimal sealing. The screw-cap design provides reliable sealing without vacuum grease — the O-ring alone ensures a tight seal.

Operation & Maintenance

User Guide

03

Before Use

  • Inspect for cracks, chips, or scratches on any joint
  • Check that the O-ring is intact and not deformed
  • Confirm thermometer O.D. is 5.0~7.5mm
  • Clean all joint surfaces with a soft cloth to remove particulates
04

Thermometer Installation

  • Insert the thermometer through the nylon cap and O-ring into the adapter
  • Adjust to the desired insertion depth (thermometer bulb position)
  • Tighten the nylon cap to create a seal around the thermometer
  • Avoid over-tightening to prevent thermometer breakage
05

Connection

  • Align the lower joint with the receiving apparatus and gently twist to seat
  • Use a clamp on the adapter body (not on joints) for support
  • For vacuum applications, ensure all joints are well-seated
06

Cleaning & Storage

  • Clean immediately after use to prevent residue buildup
  • Use soft brushes and appropriate detergents for the inner tube and joint
  • Replace O-rings if they show signs of aging
  • Air dry and store with protective paper between ground joints
  • Protect joints from impacts

Thermometer Adapter · Selection Guide

Four key dimensions determine the right thermometer adapter for your system: adapter type, joint size, tube length, and seal type.

1. By Adapter Type

TypeFeaturesTypical Use
Please contact us to confirm the available specifications.

2. By Joint Size

ScaleGB/TTypical VolumeMatching Apparatus
Please contact us to confirm the available specifications.

3. By Tube Length

Tube LengthTypical Application
Please contact us to confirm the available specifications.

4. Quick Selection Checklist

Follow this decision flow to quickly identify the right configuration:

  • ① Probe protection needed? No → Standard screw-cap  |  Yes → Sealed-bottom
  • ② Adjustable positioning needed? No → Standard  |  Yes → Adjustable
  • ③ Scale? Micro → 14#  |  Standard → 19#/24#  |  Large → 29#+
  • ④ Vessel depth? Shallow → 40mm  |  Standard → 100mm  |  Deep → 150~200mm

✦ Need help selecting? Contact our technical support team with your thermometer specifications and experimental requirements — we'll recommend the optimal configuration.

Care & Notes

Show care & notes

Safety Precautions

  • Observe temperature limits for the glass and O-ring materials
  • Wear protective gloves and safety goggles
Do not
  • Never use cracked or damaged adapters under vacuum
  • Avoid excessive force when installing thermometers

Need spec confirmation or bulk pricing?

Request a Quote
Thermometer AdapterGB/T 14 – 34 Get a Quote