Fritted
Fritted Crucible
Fritted · Fritted Crucible

Fritted Crucible

Sintered Fritted G0~G6 · 2ml ~ 100ml · Gravimetric Analysis

The fritted crucible (also known as a Gooch crucible with fritted disc or sintered glass crucible) is an essential glass instrument for gravimetric and microanalysis in the laboratory. Made from high-quality borosilicate glass 3.3 with a sintered glass frit, it is specifically designed for the combined operation of filtration, washing, drying, and weighing of precipitates. Fritted disc grades cover the G0~G6 full range (including G1A and G4A intermediate grades), with capacities from 2ml to 100ml — meeting diverse analytical needs including gravimetric analysis, ash determination, and crude fiber determination. Manufactured in compliance with GB/T 28211-2011 standards. Custom capacities and fritted disc grades are available upon request.

2 – 250ISO
0 – 6 AOriginal
1.2 – 250 μmPore Size
GB/T 28211Standard

Specifications are subject to confirmation with your enquiry.

Request a Quote
Borosilicate Glass 3.3 Sintered Fritted G0~G6 Filtration + Drying + Weighing Gravimetric Analysis GB/T 28211-2011
  • Borosilicate Glass 3.3, excellent thermal shock resistance
  • Sintered fritted disc, uniform pore size, G0~G6 full range
  • Combined filtration, washing, drying & weighing operation
  • Fritted disc firmly sintered to glass body — no detachment
  • Capacities from 2ml to 100ml, custom options available
  • Complies with GB/T 28211-2011 standards

BRAND IDENTITY

Vissal® brand wordmark RichTech company logo

Vissal® is RichTech's own brand; RichTech is the company mark. Both are used together for this product's brand identification.

We will follow up on your inquiry as soon as possible. Custom sizes supported Samples available

Specifications

Specifications

Fritted Crucible · Specifications

Standard specifications are listed below. Fritted disc grades cover G0~G6 full range (including G1A and G4A intermediate grades). Custom capacities and fritted disc grades available upon request.

Request custom specs

I. Fritted Disc Grade Guide (ISO/Original Standard)

Note: The following follows the industry-standard ISO/Original Standard classification system. Commercial systems (e.g., from brands like SunSig or some professional brands) may differ. G1A and G4A are intermediate grades offering finer pore size selection.
ISOOriginalPore Size (μm)General Use
P250C00160-250Coarse particle precipitation
P160G0100-160Coarse particle filtration, coarse gas distribution
P100G1A70-100Water treatment
P70G150-70Large precipitates and colloidal precipitates
P50G230-50Gas washing, large precipitate filtration
P30G316-30Fine precipitate filtration, mercury filtration
P16G4A7-16Fine particle filtration, fine gas distribution
P7G44-7Very fine precipitate filtration
P4G52-4Ultrafine particle filtration, large bacteria
P2G61.2-2.0Bacterial filtration (E. coli and Staphylococcus)
* Source: Industry-standard ISO/Original Standard classification system

II. Chinese National Standard (GB/T) System

GradePore Size (μm)General Use
G120~30Coarse precipitates and colloidal precipitates
G210~15Coarse precipitates, gas washing
G34.5~9Fine precipitates, mercury filtration
G43~4Very fine precipitates
G51.5~2.5Large rod-shaped bacteria and yeast
G6<1.51.5~0.6μm bacteria (discontinued by some manufacturers)
* Source: GB/T 28211-2011 related standards

III. Fritted Disc Grade Classification

CategoryGradesPore Size RangeApplications
Gas Treatment G0, G1A, G1, G2 30~160μm Suitable for coarse precipitate filtration and washing
Chemical Analysis G3, G4, G4A 4~30μm Suitable for fine precipitate filtration in general chemical analysis — gravimetric analysis, crude fiber determination (G3~G4)
Bio/Pharma G5, G6 1.2~4μm Suitable for ultrafine precipitate filtration and sterile filtration

IV. Capacity Options

Size CategoryCommon Capacities (ml)
Micro2, 5, 10
Small15, 25, 30
Medium40, 50, 60, 100

V. Fritted Crucible vs. Fritted Funnel

FeatureFritted CrucibleFritted Funnel
Core FunctionFiltration + Drying + WeighingRoutine filtration, suction
Typical UseGravimetric analysis, ash determination, crude fiberLiquid filtration, solid-liquid separation
Capacity Range2ml ~ 100ml2ml ~ 20000ml
Temperature< 500°C (drying/weighing)Routine filtration temperatures

* Custom capacities and fritted disc grades available.
* Complies with GB/T 28211-2011 standards.
* For bulk customization, please contact our sales team for MOQ and lead time.

✦ Custom Services — Non-standard capacities, fritted disc grades, and overall dimensions available. Contact us with your specific requirements and our technical team will provide a tailored solution.

Product Description

The fritted crucible (also known as a Gooch crucible with fritted disc or sintered glass crucible) is a specialized glass instrument for gravimetric analysis, microanalysis, and chemical analysis — designed for the filtration, washing, drying, and weighing of precipitates. Made from high-quality borosilicate glass 3.3 with a sintered glass frit, it offers excellent chemical resistance, thermal shock resistance, and filtration efficiency.

The key design advantage of the fritted crucible is its combined filtration + drying + weighing capability: precipitates can undergo the entire process from filtration and washing to drying and weighing within the same crucible, eliminating sample loss from transfer and improving analytical accuracy. Fritted disc grades cover the G0~G6 full range (including G1A and G4A intermediate grades), suitable for different types of precipitates.

✦ Key Advantages: Compared to standard paper filtration, fritted crucibles offer superior chemical resistance — capable of filtering acids and other corrosive systems. Precipitates are dried and weighed directly in the crucible without transfer, eliminating sample loss. Uniform pore size ensures high filtration efficiency. Reusable with proper cleaning, offering long service life.

Key Features

  • Borosilicate Glass 3.3: Low thermal expansion, chemical resistance, thermal shock resistance
  • Sintered Fritted Disc: Uniform pore size, G0~G6 full range (including G1A and G4A)
  • Filtration + Drying + Weighing: Combined operation eliminates sample transfer loss
  • Acid-Resistant: Suitable for filtering acids and corrosive reagents
  • Wide Size Range: Capacities from 2ml to 100ml
  • Reusable: Can be cleaned and reused — economical and environmentally friendly

Quality Assurance

Every fritted crucible undergoes rigorous pore size inspection, visual inspection, and material testing to ensure the frit is intact, unclogged, and has uniform pore size. Bulk orders support custom fritted disc grades and capacities — welcome to inquire.

Tip: Inspect the fritted disc for cracks or clogging before use. Clean immediately after use to prevent residue from blocking the frit pores. Maximum working temperature is 500°C — do not subject to high-temperature ashing.

Applications

Typical Applications

Gravimetric Analysis

Filtration, washing, drying, and weighing of precipitates in quantitative analysis

Ash Determination

Ash content determination in food, feed, and pharmaceuticals

Crude Fiber Determination

Crude fiber analysis in feed and food (GB/T 6434-2022)

Microanalysis

Filtration and weighing of small-volume samples

Environmental Monitoring

Suspended solids filtration and weighing in water samples

Teaching Labs

Analytical chemistry laboratory education

Applicable Standards

  • GB/T 28211-2011
  • GB/T 6434-2022
  • ASTM E438

Tip: Pre-treat new crucibles by suction filtration with hot hydrochloric acid or chromic-sulfuric acid, rinse with distilled water, and dry before use. Maximum working temperature is 500°C — do not subject to high-temperature ashing.

Operation & Maintenance

Fritted Crucible User Guide

03

I. Before Use

  • Inspect the fritted disc for cracks, defects, or clogging
  • New crucibles should be pre-treated by suction filtration with hot hydrochloric acid or chromic-sulfuric acid
  • Rinse thoroughly with distilled water
  • Dry to constant weight in an oven at 160-250°C before use
  • Important: Fritted crucibles are NOT suitable for high-temperature ashing — maximum working temperature is 500°C
04

II. Filtration & Weighing Procedure

  • Mount the fritted crucible securely on the filter flask
  • Pour the precipitate suspension slowly along a glass rod into the crucible
  • Wash the precipitate with appropriate solvent (washing volume generally ≤ 2/3 of crucible capacity per wash)
  • After filtration, place the crucible with precipitate in the oven
  • Dry at 110-250°C to constant weight
  • Cool in a desiccator to room temperature, then weigh
  • Repeat drying-cooling-weighing cycles until constant weight is achieved
05

III. Cleaning & Maintenance

  • Clean immediately after use to prevent residue from hardening
  • Soak in potassium dichromate-sulfuric acid cleaning solution overnight
  • Alternatively, soak in concentrated sulfuric acid with heating for 1 hour
  • Do not use scouring powder
  • Do not scrape the fritted disc with hard objects
  • Rinse thoroughly with distilled water and dry before storage
Precipitate TypeRecommended Cleaning Solution
Fats, lipidsCarbon tetrachloride or other organic solvents
Organic matterHot chromic acid cleaning solution, or concentrated sulfuric acid with potassium nitrate and potassium perchlorate
Proteins, mucusHydrochloric acid, hot ammonia water, or hot sulfuric-nitric acid mixture
Mercury residueHot concentrated nitric acid

Fritted Crucible · Selection Guide

Selecting the right fritted crucible involves three key considerations: fritted disc grade, capacity, and analysis type.

I. By Fritted Disc Grade

GradePore Size (μm)Precipitate TypeTypical Application
G1, G230-70Coarse, colloidal precipitatesGeneral coarse precipitate filtration
G3, G4A7-30Fine crystalline precipitatesGravimetric analysis, crude fiber determination
G4, G52-7Very fine precipitatesMicroanalysis, precision weighing
G61.2-2.0Bacterial-level particlesSterile filtration, microbiological analysis

II. By Analysis Type

Analysis TypeRecommended GradeRecommended Capacity
Gravimetric AnalysisG3, G415ml, 30ml, 50ml
Ash DeterminationG3, G430ml, 50ml
Crude Fiber DeterminationG3, G440ml, 60ml
MicroanalysisG4, G52ml, 5ml, 10ml

III. Quick Selection Checklist

  • ① Analysis purpose? Gravimetric → G3-G4  |  Crude fiber → G3-G4  |  Microanalysis → G4-G5
  • ② Precipitate type? Coarse → G1-G2  |  Fine → G3-G4  |  Ultrafine → G5-G6
  • ③ Sample volume? Micro (< 10ml) → 2-10ml  |  Routine (10-50ml) → 15-50ml  |  Large (>50ml) → 60-100ml

✦ Need help selecting? Contact our technical support team with your analytical requirements and operating conditions — we'll recommend the optimal configuration.

Care & Notes

Show care & notes

Safety Precautions

  • Always work in a fume hood when handling strong acids, bases, or flammable liquids
  • Wear protective gloves and safety goggles
Do not
  • Do not use cracked or damaged fritted products
  • Pressure differential across the frit must not exceed 9.8×10⁴ Pa (1 kg/cm²)
  • Do not apply direct flame — high heat can sinter the frit into a solid block
  • NEVER filter: Hydrofluoric acid, hot concentrated phosphoric acid, or hot/cold concentrated alkali solutions