Apparatus Kit
HPLC Solvent Filtration Apparatus
Image coming soon hplc-filtration.jpg
Filtration · HPLC Solvent Filtration Apparatus

HPLC Solvent Filtration Apparatus

47mm Glass Frit Base · 300ml Funnel · 1000ml Receiver

The HPLC solvent filtration apparatus is an essential sample preparation tool in HPLC workflows. Vacuum filtration removes particulates, undissolved salts, and microbes from mobile phases and samples — 0.2μm or 0.45μm membranes catch what needs to be caught. No clogged columns, no drifting baselines, no ruined pumps — all it takes is this one step. The funnel, base, and receiver are all made from borosilicate glass 3.3 — corrosion-resistant, pressure-rated, and compatible with standard 47mm membranes.

Glass Funnel / Fritted Glass Base …Component
8 – 1000 graduatedStandard Spec
250ml 500ml / Stainless steel support …Upgrade Options
1 – 100Qty

Specifications are subject to confirmation with your enquiry.

Request a Quote
Borosilicate Glass 3.3 Compatible with 47mm Membranes 300ml Graduated Funnel Complete with Vacuum Pump

📐 Selection Guidelines: Membrane pore size: 0.45μm for routine mobile phases, 0.22μm for sterile filtration and protein samples. Membrane material: MCE for aqueous, Nylon or PTFE for organic, RC for general use. Receiver volume: 1000ml is standard, 2000ml for larger batches. A vacuum pump with 20L/min flow and -0.08MPa ultimate vacuum is sufficient for most applications.

  • Membrane recommendations — aqueous, organic, or general-purpose — we'll help you pick
  • Borosilicate Glass 3.3 — corrosion-resistant, pressure-rated, crystal clear
  • 47mm Standard Membrane Compatible — easy to find consumables
  • 300ml Graduated Funnel — volume markings for easy measurement
  • Complete with Vacuum Pump — oil-free diaphragm, corrosion-resistant, maintenance-free

BRAND IDENTITY

Vissal® brand wordmark RichTech company logo

Vissal® is RichTech's own brand; RichTech is the company mark. Both are used together for this product's brand identification.

We will follow up on your inquiry as soon as possible. Custom sizes supported Samples available

Specifications

Specifications

Component List

All components listed below are included in this kit. Items marked Optional can be customized.

Request custom specs
Component Standard Spec Upgrade Options Qty Link
Please contact us to confirm the available specifications.
📌 Customization Notes:
• Receiver capacity: 1000ml (standard), 2000ml — choose based on volume
• Membranes: MCE (aqueous), Nylon (organic), PTFE (aggressive), RC (general)
• Vacuum pump: Standard or Corrosion-resistant — corrosion-resistant recommended for organic solvents
• Mix and match — no minimum order quantity
• Special requirements? Just ask our technical team
💡 Recommended Add-Ons: Spare membranes (multiple grades) · GL45 serum bottles (direct receiver/storage) · Vacuum pump spare parts · Solvent bottle adapters

Product Description

I. Why Filter Mobile Phases

HPLC column packing is fine (typically 3–5μm), and the column frit is even finer — 0.5–2μm. Any particles in the mobile phase — undissolved salts, dust, microbes, precipitated buffer salts — will clog that frit. The result? Rising backpressure, poor peak shape, drifting baseline, and in the worst case, a dead column.

Filtering mobile phases costs very little, but it saves a lot — a good HPLC column costs hundreds or thousands, while a filtration setup lasts for years. A quick filtration every day extends column life significantly.

✦ What happens if you don't filter (real stories):

① Backpressure creeps up until the system alarms and shuts down
② Peaks broaden, tail, or show ghost peaks
③ Pump seals wear out — frequent replacements
④ Baseline noise increases — detection limits suffer
⑤ Worst case — a brand new column dies in a month

II. What's in the Setup

  • Glass Funnel — 300ml with graduations, for pouring mobile phase
  • Fritted Glass Filter Base — 47mm standard size, holds the membrane
  • Receiver Flask — 1000ml or 2000ml, collects filtered mobile phase
  • Aluminum Clamp — seals funnel to base, prevents leaks
  • Silicone Stopper — seals the receiver flask mouth
  • Vacuum Pump — oil-free diaphragm type, provides negative pressure
  • Vacuum Tubing — connects the base to the pump

III. Choosing the Right Membrane

Two things matter: pore size and material.

  • Pore size: 0.45μm is the standard — removes most particles and microbes. 0.22μm is finer — removes bacteria, suitable for biological samples and protein analysis.
  • Material:
    • MCE (Mixed Cellulose Ester) — aqueous only, inexpensive, hydrophilic
    • Nylon — solvent-resistant, good for methanol and acetonitrile
    • PTFE — resistant to acids, bases, and all organic solvents — pre-wet required for aqueous
    • RC (Regenerated Cellulose) — general-purpose, works with both aqueous and organic

If you're unsure, 0.45μm Nylon is the most versatile — works with acetonitrile, methanol, and water.

IV. Material & Workmanship

The funnel, base, and receiver are all made from borosilicate glass 3.3 — chemically resistant, heat-tolerant, and transparent. The sintered glass frit in the base has uniform pores for flat membrane support. The aluminum clamp is anodized for corrosion resistance and even clamping force.

Applications

Typical Applications

HPLC Mobile Phase Filtration

Acetonitrile, methanol, aqueous buffers, salt solutions — a daily essential

Sample Preparation

Pre-injection filtration to protect columns and detectors

Buffer Purification

Removing undissolved salts and microbes from buffer solutions

Solvent Degassing

Vacuum filtration simultaneously removes dissolved gases — reduces baseline noise

Microbiological Testing

0.22μm membranes for sterile filtration and microbial retention

Gravimetric Analysis

Collecting particulates on the membrane for weighing

Solvent TypeRecommended MembranePore SizeNotes
Please contact us to confirm the available specifications.
Operation & Maintenance

User Guide

HPLC solvent filtration looks simple, but a few details make the difference between effective filtration and wasted effort.

03

I. Before You Start

  • Check all glass components for cracks — cracked glass is unsafe under vacuum
  • Make sure you've selected the right membrane — hydrophilic for aqueous, hydrophobic for organic
  • Check the silicone stopper — is it intact and the right size?
  • Check the vacuum pump (oil level if applicable) and tubing for blockages
04

Assembly sequence

  1. Insert the silicone stopper into the receiver flask mouth
  2. Insert the fritted glass base into the stopper
  3. Using tweezers, lay the membrane flat on the frit, making sure it completely covers the frit surface
  4. Place the funnel on top, pressing down on the membrane
  5. Clamp the funnel and base together with the aluminum clamp — leaks kill vacuum
  6. Connect vacuum tubing from the base's vacuum port to the pump
05

III. Wet the Membrane (Critical!)

  • Pour a small amount of your solvent into the funnel, then turn on the vacuum briefly to completely wet the membrane
  • Turn off the vacuum and check for air bubbles under the membrane — bubbles block flow and reduce filtration efficiency
  • PTFE membranes need special attention — they're hydrophobic. Pre-wet with methanol or isopropanol before filtering aqueous solutions
06

IV. Filtration

  • Pour the mobile phase into the funnel — decant the clear supernatant first, and save the sediment for last
  • Turn on the vacuum pump and adjust to -0.06~-0.08MPa
  • Watch the filtration speed — 300ml should take 1–3 minutes under normal conditions
  • If the flow suddenly slows down, the membrane is probably clogged — replace it with a fresh one
06

V. Shutdown & Collecting Filtrate

  • Disconnect the vacuum tubing FIRST (or open the vent valve) to release vacuum
  • Then turn off the pump — reverse the order and you'll get suck-back
  • Filtered mobile phase is in the receiver — pour it out for use, or cap and store
  • If your receiver is a GL45 serum bottle, just cap it and take it straight to the HPLC
06

VI. Cleaning

  • Disassemble all components — funnel, base, receiver, stopper
  • Wash glass parts with detergent, rinse thoroughly with tap water, then rinse with distilled water
  • Wash the silicone stopper with water and wipe dry
  • Air-dry glass parts — do not oven-dry at high temperatures — thermal shock can cause cracking

📌 What happens if the membrane isn't flat:

If the membrane is wrinkled, folded, or doesn't fully cover the frit — liquid will bypass through the gap between the membrane and the frit, and the filtration is useless.
Use tweezers — don't touch the membrane with your fingers. Skin oils contaminate it.

💡 From a Seasoned Lab Hand:

"Don't skip the membrane wetting step." — People skip it to save time, then wonder why filtration is painfully slow. Air bubbles trapped under a dry membrane block flow — it's not the pump's fault.
If filtration is unusually slow, check three things: ① Is the vacuum level sufficient? ② Is the membrane clogged? ③ Is the stopper leaking?
Membranes are single-use only — once used, the pores are partially blocked. Reusing them means incomplete filtration.
Use filtered mobile phase the same day — microbes can grow back overnight.

Care & Notes

Show care & notes

⚠️ Safety & Compliance Checklist

Shutdown sequence is non-negotiable

Disconnect (or vent) first, then turn off the pump — this is the universal rule for vacuum filtration

Solvent compatibility

Always confirm your membrane material is compatible with your solvent — incompatible membranes can dissolve or deform

Organic solvents

Work in a fume hood and wear solvent-resistant gloves

Do not
  • Glassware: Never use cracked glassware under vacuum — it can implode
  • Do NOT filter: Hydrofluoric acid, hot concentrated phosphoric acid, or hot/cold concentrated alkali — they'll corrode the glass

Need This Apparatus Kit?

Contact our team for pricing and availability. Custom configurations are available.

HPLC Solvent Filtration ApparatusComponent Glass Funnel / Fritted Glass Base … Get a Quote