The Agilent HPLC solvent inlet filter head is the first critical protective barrier in the HPLC system, used for inline filtration of particulate matter, precipitates, and microorganisms from mobile phases, buffers, and salt solutions — effectively preventing column clogging and pump system wear. Made from high-quality borosilicate glass 3.3 with a sintered fritted disc, it is compatible with mainstream Agilent systems including 1100, 1200, 1260, and 1290 series. Available in analytical (20μm) and preparative (40μm) pore sizes, complete with PTFE fittings for easy installation and reliable sealing. Custom specifications are available upon request.

Analytical / Preparative …Type
20μm / 40μm …Pore Size
Borosilicate Glass 3.3 / Stainless SteelMaterial
1100/1200/1260/1290 / Preparative LC systems …Compatible Systems

Specifications are subject to confirmation with your enquiry.

Request a Quote
Borosilicate Glass 3.3 Sintered Frit 20μm/40μm Analytical/Preparative Compatible with Agilent Systems Inline Solvent Filtration
  • Borosilicate Glass 3.3, excellent chemical resistance
  • Sintered frit, uniform pore size, 20μm/40μm options
  • Compatible with Agilent 1100/1200/1260/1290 series
  • Complete with PTFE fittings, easy installation
  • Traps particles, precipitates, and microorganisms
  • High transparency for easy visual inspection

BRAND IDENTITY

Vissal® brand wordmark RichTech company logo

Vissal® is RichTech's own brand; RichTech is the company mark. Both are used together for this product's brand identification.

We will follow up on your inquiry as soon as possible. Custom sizes supported Samples available

Specifications

Specifications

Agilent HPLC Filter Head · Specifications

Standard specifications are listed below. Custom specifications available upon request.

Request custom specs

I. Specification Table

TypePore SizeMaterialCompatible SystemsFitting
Analytical 20μm Borosilicate Glass 3.3 1100/1200/1260/1290 5062-8517 (PTFE, 3mm)
Preparative 40μm Borosilicate Glass 3.3 Preparative LC systems G1361-23204 (4mm) / G1361-23205 (4.7mm)
Stainless Steel — Stainless Steel Capillary/Nano LC —
* Compatible with Agilent and compatible HPLC systems.

II. Fitting Information

Part No.MaterialSpecificationCompatible Filter
5062-8517PTFE3mmAnalytical (20μm)
G1361-23204PTFE4mmPreparative (40μm)
G1361-23205PTFE4.7mmPreparative (40μm)

III. OEM Equivalent Guide

Our ProductEquivalent OEM Part No.
Analytical 20μm5041-2168
Preparative 40μm3150-0944
* Our product is a direct equivalent alternative with comparable performance at better value.

* Custom specifications and bulk procurement solutions available.
* For bulk customization, please contact our sales team for MOQ and lead time.

✦ Custom Services — Non-standard pore sizes, custom dimensions, and large-volume orders available. Contact us with your specific requirements and our technical team will provide a tailored solution.

Product Description

The Agilent HPLC solvent inlet filter head is an inline filter installed at the entrance of the mobile phase solvent bottle — the first critical protective barrier in the HPLC system. Its core function is to trap particulate matter, precipitates, and microorganisms from mobile phases, buffers, and salt solutions, preventing column clogging, pump seal wear, and check valve failure — ensuring stable system operation and extended column life.

Manufactured from high-quality borosilicate glass 3.3 with a sintered fritted disc, the filter features uniform pore size distribution and high filtration efficiency. Available in analytical (20μm) and preparative (40μm) specifications, compatible with mainstream Agilent systems including 1100, 1200, 1260, and 1290 series. Complete with PTFE fittings for excellent chemical compatibility, easy installation, and reliable sealing.

✦ Key Advantages: Offering comparable filtration precision and reliability to original OEM filters at a more cost-effective price point. The glass frit structure provides excellent permeability with low flow resistance; high transparency allows easy visual inspection of filter condition; cleanable and reusable for economic and environmental benefits.

Key Features

  • Borosilicate Glass 3.3: Chemically resistant, suitable for common HPLC solvent systems
  • Sintered Frit: Uniform pore size, high filtration efficiency, 20μm/40μm options
  • System Protection: Traps particles, precipitates, and microorganisms
  • Broad Compatibility: Fits Agilent 1100/1200/1260/1290 series
  • PTFE Fittings: Chemical compatibility, reliable sealing
  • Cost-Effective: Cleanable and reusable, reducing operating costs

Quality Assurance

Every filter head undergoes rigorous pore size inspection, visual inspection, and seal integrity testing to ensure perfect compatibility with Agilent HPLC systems. Bulk orders support custom specifications — welcome to inquire.

Important: This product is made of glass frit — DO NOT sonicate. For clogged filters, soak in dilute nitric acid. Glass filters are NOT compatible with hydrofluoric acid or strong alkaline systems — use stainless steel filters for such applications.

Applications

Typical Applications

HPLC Mobile Phase Inline Filtration

Removing particles, precipitates, and microorganisms from mobile phases

Buffer Filtration

Removing impurities from buffers to prevent salt crystallization

Column Protection

Acting as the first barrier to extend column life

Preparative LC

High-flow preparative-grade filtration (40μm)

Micro/Nano LC

Stainless steel filters for capillary and nano-flow LC systems

QC/QA Testing

Routine quality control laboratory sample analysis

Compatible Systems

Agilent 1100/1200/1260/1290 Series HPLC

Agilent Preparative LC Systems

Compatible with major brand LC systems (verify fitting compatibility)

Tip: Before installation, flush the filter head with mobile phase to remove any residual impurities from shipping. Regularly inspect the filter condition — replace immediately if significant contamination or flow rate reduction is observed.

Operation & Maintenance

Agilent HPLC Filter Head User Guide

03

I. Before Use

  • Inspect the filter head for cracks, defects, or clogging
  • Verify the pore size matches your system requirements
  • Confirm the correct fitting model
  • Flush with mobile phase to remove shipping residues
04

II. Installation Steps

  • Attach the PTFE fitting to the solvent tubing
  • Connect the glass filter head to the fitting, ensuring a good seal
  • Fully submerge the filter head in the solvent bottle
  • Start the pump and check for air bubbles from the filter head
  • Verify normal flow rate and stable system pressure
05

III. Clogged Filter Treatment

  • ⚠️ DO NOT use ultrasonication: Ultrasonic cleaning can crack or alter the pore size of the glass frit
  • Recommended method: Soak the filter head in 30%~35% dilute nitric acid solution for approximately 1 hour
  • Rinse thoroughly with large volumes of ultrapure water
  • If severely clogged and cannot be cleared, replace with a new filter
06

IV. Maintenance Schedule

  • Inspect filter condition after every 5-10 mobile phase changes
  • If significant discoloration, reduced flow rate, or increased pressure is observed, treat or replace immediately
  • Regularly check fitting seals for leaks
06

V. Mobile Phase Change Precautions

  • Be careful not to bump the glass filter head when changing mobile phases
  • When switching solvents, use an intermediate solvent for transition
  • For long-term storage, keep the filter head immersed in methanol or acetonitrile

Agilent HPLC Filter Head · Selection Guide

Selecting the right filter head involves three key considerations: system type, tubing size, and chemical system.

I. By System Type

System TypeRecommended Pore SizeFittingCompatible Models
Analytical HPLC20μm5062-8517 (3mm)1100/1200/1260/1290
Preparative HPLC40μmG1361-23204/G1361-23205Preparative LC systems
Capillary/Nano LCStainless Steel—Capillary LC systems

II. By Chemical System

Chemical SystemRecommended MaterialNotes
Routine RP/NP solventsGlass (20μm/40μm)Organic solvent resistant, high transparency
Strong acid (non-HF) systemsGlassGood acid resistance
Hydrofluoric acid systems❌ Glass NOT recommendedHF etches glass — use stainless steel
Strong alkaline systems❌ Glass NOT recommendedStrong bases etch glass — use stainless steel

III. Quick Selection Checklist

  • ① LC system type? Analytical → 20μm (5041-2168)  |  Preparative → 40μm (3150-0944)
  • ② Tubing outer diameter? 3.2mm → 5062-8517  |  4.0mm → G1361-23204  |  4.7mm → G1361-23205
  • ③ Mobile phase contains HF or strong base? Yes → Stainless Steel filter  |  No → Glass filter

✦ Need help selecting? Contact our technical support team with your system model and experimental conditions — we'll recommend the optimal configuration.

Care & Notes

Show care & notes

Safety Precautions

  • Glass filters are NOT compatible with hydrofluoric acid or strong alkaline mobile phases — use stainless steel for such applications
  • Work in a well-ventilated area when handling organic solvents
  • Wear protective gloves and safety goggles
  • Monitor system pressure changes when changing mobile phases
Do not
  • Do not use cracked or damaged filter heads

Need spec confirmation or bulk pricing?

Request a Quote
Agilent HPLC Filter HeadType Analytical / Preparative … Get a Quote