Quartz Three Neck Flask

Quartz glass
Quartz glassMaterial
Request a Quote

Quartz Three Neck Flask cover a wide range of items within one broad category; their purpose, working conditions and pairing differ considerably between models. Please confirm against your actual operation before fixing a specification; final specifications and availability are subject to quotation.

Material per specification Custom sizes available Samples available Bulk & OEM supply Selection support

Check the item is clean and free of cracks or chips before use; avoid mechanical impact and follow the requirements of the specific model; specifications are subject to quotation.

  • Use — mainly for various laboratory operations
  • Application — typically in daily laboratory work
  • Selection — confirm interface and material against the working conditions
  • Supply — custom sizes available, samples can be shipped

BRAND IDENTITY

Vissal® brand wordmark RichTech company logo

Vissal® is RichTech's own brand; RichTech is the company mark. Both are used together for this product's brand identification.

We will follow up on your inquiry as soon as possible. Custom sizes supported Samples available

Product Description

1. Overview

The Quartz Three Neck Flask belongs to our quartz glassware and is mainly used for routine laboratory work. Standard sizes cover 25ml~5000ml. For daily preparation, transfer and support work.

The body is made of quartz glass (SiO₂ ≥ 99.9%); far better thermal shock resistance than ordinary glass, suited to rapid heating/cooling and high-temperature ashing. It works between above 1100℃ continuous, up to 1450℃ short-term; chemically it resists most acids (except hydrofluoric) and neutral salt solutions; limited alkali resistance at high temperature; very high transmittance including UV, extremely low thermal expansion. Level, interface and residue are easy to read, keeping transfer errors small.

When selecting, confirm medium, temperature and connection first, then fix the size: the medium decides the material, the temperature decides whether heating or autoclaving is possible, and the connection decides whether it mates with existing apparatus. For duties outside the normal range — hot concentrated alkali, fluoride media, vacuum or repeated thermal cycling — our engineers can confirm a suitable option.

2. Key properties

  • Material: quartz glass (SiO₂ ≥ 99.9%)
  • Working temperature: above 1100℃ continuous, up to 1450℃ short-term
  • Chemical resistance: resists most acids (except hydrofluoric) and neutral salt solutions; limited alkali resistance at high temperature
  • Surface: very high transmittance including UV, extremely low thermal expansion
  • Sterilisation: flame or high-temperature sterilization, also autoclavable
  • Size range: 25ml~5000ml

3. Manufacturing and inspection

Parts are hot-worked from quartz tube or plate with an oxy-hydrogen flame, flame annealed to relieve stress; joints ground in pairs, keeping items of the same size interchangeable. Work is carried out at controlled stations to prevent scratches and cross-contamination.

Each item is checked for appearance, dimensions and fit before dispatch; sampling covers capacity or graduation deviation, joint fit and wall uniformity. Items from the same batch stay consistent in size and feel, which simplifies central storage and reordering. Inspection records and batch information are available with the goods.

Applications

Typical applications

Purpose by model

This category covers many items with differing duties; refer to the specific model and quotation.

Daily laboratory work

Suited to daily sampling, handling and pairing.

Confirm duty first

Define the medium, handling method and interface before choosing a model.

Set-up building and modification

Connects, diverts and reduces so that parts with different joints form a complete train.

Gas and liquid path control

Handles on-off, splitting and regulation as a common node in gas and dropping circuits.

Teaching and training

Clear structure makes it easy to explain connection order and handling.

Selection Guide

Choose by duty

Duty first, size second

Define the handling method, contact medium and temperature range before choosing material and interface.

Interface must match

Confirm the interface form before pairing with other apparatus; mismatches leak or will not assemble.

Material by medium

Choose material according to the contact medium and operating temperature; refer to the specification block.

Special requirements on request

Non-standard sizes, special interfaces or volume customisation are quoted separately.

Size versus throughput

Match size to the volume per run and the number of runs a day; oversize vessels add cleaning load, undersize ones force repeated batches.

Reading accuracy needed

Choose graduated or single-mark items when accurate metering matters; skip the accuracy premium for rough transfer work.

Service condition guide

ConditionSuitabilityNotes
High-temperature heating and ashingSuitableabove 1100℃ continuous, 1450℃ short-term
Rapid heating and coolingSuitablevery low expansion, better shock resistance than ordinary glass
Water bath and thermostatic workSuitableno restriction in routine use
Hydrofluoric acid / fluoridesNot suitablequartz is attacked by HF as well
Hot strong alkaliNot suitablealkali etches quartz at high temperature
UV and optical workSuitableUV-transparent, suited to optical and spectral use
Trace analysisSuitablehigh-purity material with low metallic impurities
AutoclavingSuitablecan also be sterilised by high-temperature flaming

Usage Guide

Standard procedure

01

Step 01

Inspect for cleanliness, cracks and chipped edges before use; a crack spreads quickly under heat or load, so retire the item at once and never patch it.

02

Step 02

Assemble as required for various laboratory operations and confirm the connection is secure.

03

Step 03

Pour or transfer slowly along the wall to avoid impact on the base and splashing; with volatile or foaming media a slow stream cuts losses and cross-contamination.

04

Step 04

Quartz glass withstands high temperature and has a low expansion coefficient; avoid rapid cooling after heating.

05

Step 05

Clean promptly after use and choose the drying method according to the material; soak stubborn residues first and never scrape the wall with hard tools.

06

Step 06

Before first use, clean according to the material; soak in dilute acid where appropriate, rinse thoroughly and dry. New items may carry processing aids, so clean before contact with samples.

07

Step 07

Store without stacking or impact, in a ventilated and dry place; long stacking deforms the base, and volumetric ware should stand on its own.

08

Step 08

Keep one batch together and label different sizes separately to avoid picking the wrong item; once mixed, the batch is hard to identify when a problem appears.

09

Step 09

Keep a usage log with the commissioning date, media contacted and cleaning method, so replacement timing and traceability stay clear.

Maintenance & Notes

⚠️ Safety & handling notes

Avoid thermal shock

Sudden temperature changes create stress, especially in thick walls and wide openings; heat and cool gradually.

Prevent mechanical damage

Avoid impact, dropping and scratching; never carry by a thin or weak section.

Clean promptly

Clean immediately after use; dried residues are harder to remove. Avoid abrasive cleaning tools.

Drying by material

Air-dry or dry at low temperature; volumetric ware must never be oven-dried.

Periodic inspection

Check for cracks, deformation and seal failure after long use and replace when needed.

Identification and traceability

Items should carry a clear label and usage record; mixed use makes cleaning history and media contact untraceable.

Retirement criteria

Stop using an item for critical work once it is cracked, chipped, worn at the graduations or leaking; never patch and return it to service.

Need spec confirmation or bulk pricing?

Request a Quote
Get a Quote